低噪声红外辐射计设计

胡铁力;申越;郭羽;范纪红;马世帮;张玫;刘瑞星;谢毅;辛舟

应用光学 ›› 2013, Vol. 34 ›› Issue (4) : 663-666.

应用光学 ›› 2013, Vol. 34 ›› Issue (4) : 663-666.

低噪声红外辐射计设计

  • 胡铁力1, 申越2, 郭羽1, 范纪红1, 马世帮1, 张玫1, 刘瑞星1, 谢毅1, 辛舟1
作者信息 +

Low noise infrared radiometer

  • HU Tie-li1, SHEN Yue2, GUO Yu1, FAN Ji-hong1, MA Shi-bang1, ZHANG Mei1, LIU Rui-xing1, XIE Yi1, XIN Zhou1
Author information +
文章历史 +

摘要

为解决热像仪测试设备校准问题,设计了内部参考黑体温度与环境温度相等的红外辐射计。为评估精密红外辐射计的性能指标,指导精密红外辐射计的设计,建立了红外辐射计NETD (噪声等效温差,Noise equivalent temperature difference)数学模型。估算了在不同电子带宽、光谱波段下红外辐射计的NETD。结果表明,当噪声带宽小于1 Hz时,红外辐射计自身的NETD在MWIR(mid-wavelength infrared )、LWIR(long wavelength infrared)波段均小于0.01℃,能够满足热像仪测试设备校准需要。

Abstract

In order to solve the calibration of the infrared imager test equipment, a kind of infrared radiometer in which the temperature of interior reference blackbody was equal to the environmental temperature was designed. In order to evaluate this kind of radiometer and give guidance to the infrared radiometer design, a mathematic model for infrared radiometer noise equivalent temperature difference (NETD)was given. The NETD of infrared radiometer was estimated under different electronic bandwidths and spectral wavebands. The results show that when noise equivalent bandwidth is within 1 Hz, NETD of infrared radiometer in mid-wavelength infrared (MWIR) and long wavelength infrared (LWIR) spectral bands is smaller than 0.01℃, which can meet the requirements of the calibration of infrared imager test equipment.

关键词

红外辐射计 / 辐射温度 / 黑体 / 噪声等效温差 / 红外热像仪

Key words

radiant temperature / infrared imager / infrared radiometer / NETD / blackbody

引用本文

导出引用
胡铁力, 申越, 郭羽, 范纪红, 马世帮, 张玫, 刘瑞星, 谢毅, 辛舟. 低噪声红外辐射计设计. 应用光学. 2013, 34(4): 663-666
HU Tie-li, SHEN Yue, GUO Yu, FAN Ji-hong, MA Shi-bang, ZHANG Mei, LIU Rui-xing, XIE Yi, XIN Zhou. Low noise infrared radiometer. Journal of Applied Optics. 2013, 34(4): 663-666

参考文献

[1]胡铁力,李旭东,付建明,等. 红外热像仪参数的双黑体测量装置 [J]. 应用光学,2006,27(3):246-249.
HU Tie-li, LI Xu-dong,FU Jian-ming,et al. Double-blackbody unit for measuring parameters of infrared cameras [J]. Journal of Applied Optics, 2006,27(3):246-249.(in Chinese with an English abstract)
[2]BRYANT P,  GRIGOR J,  MCHUGH S,et al. Performance comparison of reflective and emissive target projector systems for high-performance IR sensors [J]. SPIE, 2003, 5076:242-249.
[3]胡铁力,韩军,郑克哲,等. 红外热像仪测试系统校准[J]. 应用光学,2006,27 (增刊):28-32.
HU Tie-li, HAN Jun,ZHENG Ke-zhe,et al. Calibration facility of infrared imaging systems [J]. Journal of Applied Optics, 2006,27(Sup):28-32.(in Chinese with an English abstract)
[4]MACKINNON J B,  SMITH B R,  SCHWEIZER F. Calibration of a transfer radiometer in support of the navy forward looking infra