分析了腔平移镜这一引起激光陀螺光路变动的主要因素,旨在揭示腔平移镜影响激光陀螺内部光路的机理及其影响的大小。通过分析计算得出,腔平移镜歪扭引起激光陀螺内部光束通过光栏中心位置时产生的横向位移相当于光栏半径10%~20%的变化。通过搭建光路测试系统,验证了腔平移镜歪扭的变化主要造成了激光陀螺内部光束通过光栏中心位置的变化这一结论,分析了这一变化对激光陀螺性能影响的机理。
Abstract
The mirror transducer assembly causing light path variation of ring laser gyro is analyzed. This analysis reveals how the action mechanism of the mirror transducer assembly influences light path in ring laser gyro and to what extent it may have. The calculated results indicate that mirror tilt can induce a light path shift of about 10~20% aperture diameter at the aperture transverse section. A test system is built to verify that it is the tilt of mirror transducer assembly which causes the light path variation at the aperture. At last, the impact of the action mechanism of light path variation on ring laser gyro performance is discussed.
关键词
腔平移镜 /
环形谐振腔 /
镜片歪扭 /
光栏 /
激光陀螺
{{custom_keyword}} /
Key words
mirror tilt /
ring laser gyro /
ring resonator /
aperture /
mirror transducer assembly
{{custom_keyword}} /
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1]高伯龙,李树棠.激光陀螺[M].长沙:国防科技大学出版社,1984.
GAO Bo-long, LI Shu-tang. The ring laser gyro[M]. Changsha: Press of National University of Defense Technology,1984.(in Chinese)
[2]SHUTT S G. Phase-coded control for ring laser gyro:US, 4099876[P]. 1978-06-11.
[3]金世龙,龙兴武,张斌,等.空间正交三轴激光陀螺的调腔技术[J].光学技术, 2005,31(04):525-529.
JIN Shi-long, LONG Xing-wu, ZHANG Bin, et al. Cavity adjustment technology for orthogonal triaxial ring laser gyro[J]. Optical Technique, 2005,31(04):525-529.(in Chinese with an English abstract)
[4]高伯龙,姜亚南.朗缪尔流动的零漂效应[J].国防科技大学学报, 1980,3l(3):30-50.
GAO Bo-long, JIANG Ya-nan. Langmuir flow effects in laser gyro drift[J]. Journal of National University of Defense Technology,1980,31(3):30-50. (in Chinese with an English abstract)
[5]杨未强. 外围部