A new method of dynamically calibrating temperature sensor to be checked was presented by a dynamic calibration system, which takes a high frequency modulated high power C〇2 laser as heat source and makes radiation thermometer, i.e. infrared detector, calibrated statically. For frequency- response characteristic of high speed radiation thermometer surpasses that of the temperature sensor, it can be used as the reference value to calibrate the latter and let the system error be corrected, to avoid the errors caused by the difference environment of installed sensor and the change of thermo- physical property and solve the difficult problem of traceable dynamic calibration of temperature sensor. CHAL- 010 thermocouple made in U.S. OMEGA Co. was calibrated dynamically by the method wmch has better repeatability to obtain its time constant and corrected value of dynamic temperature measuring error.
Key words
technology of instrument and meter /
thermocouple /
surface-temperature /
dynamic-bration /
response time
{{custom_keyword}} /
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
References
[1] Michalski L,EcKersdori K,Kucharski J, et al. Temperatures measurement[ M ]. zna ed. Chichester: Jonn Wiley & Sons, 2001:279-332.
[2] Nicholas J V, White D R. Traceable temperatures: an introduc?tion to temperature measurement and calibration [ M ]. 2na ed. Chichester: John Wiley & Sons,2001:21 — 24.
[3] ZHOU Han-chang, PAN De-heng, LAN Jin-hu1. A dynamic cali?bration system for transcient surface temperature transducers [ C ] Il Instrumentation and Measurement Technology' Conference, Hamamatsu: Hamamatsu University, 1994: 273-270.
[4] 梁列国,周汉昌,潘德恒.瞬态表面温度传感器的校准技术研 究[J].兵工学报,2001,22(2) :263-265.
LIANG Lie-guo, ZHOU Han-chang, PAN De-heng. A study on the method of calibration for transient surface temperrature detec- tors[J]. Acta Armamentarii, 2001,22(2) : 263 - 265. (in Chi?nese)
[5] Waldemar Minkina. Theoretical and experimental identification of the temperature sensor unit step response non-linearity during air temperature measurement^J]. Sensors and Actuators, 1999,78: 81-87.
[6」 Cherii 0 L, Abdallah K. Periodic method: correction for thermo?couple and simultaneous estimation of thermal conductivity and thermal diffusivity[ J ]. Review of Scientific Instruments, 2004, 75(7):132-135.
[7] Mano J F, Cahon J P. A simple method for calibrating the tem?perature in dynamic mecnanical analysers and thermal mechanical analysers[j]. Polymer Testing, 2004,23 : 423 - 430.
[8] ZHOU Han-chang, HAO Xiao-jian. Traceable dynamic calibration for high1 temperature sensors using CO2 laser [C] /j IEEE of Sen?sors, Korea: Daegu, 2006: 1349 -1352.
[9] ZHOU Han-chang, HAO Xiao-jian. Traceable dynamic calibration for high temperature sensors[C]//Measurement Science Confer-ence, US: Long Beach, 2007: 329 - 332.
[10] 郝晓剑.瞬态表面高温测量与动态校准技术研究[D].太原: 中北大学,2005.
HAO Xiao-jian. fransient high suriace temperature measure?ment ana dynamic caiibration[Dj. Taiyuan: North University ot China, 2005. (in Chinese)
[11] 黄亮.瞬态表面温度传感器动态校准技术研究[D].太原:中 北大学,2007.
HUANG Liang. Research on dynamic calibration technology ot transient surface temperature sensor[D]. Taiyuan: North Uni?versity of China, 2007. (in Chinese)
[12] 孟宪文.瞬态表面温度传感器动态测量误差补偿技术研究 [D].太原:中北大学,2007.
MENG Xian-wen. Research on dynamic measurement errors compensation technology of transient surface temperature sensor [D]. Taiyuan: North University of China, 2007. (in Chinese)
{{custom_fnGroup.title_en}}
Footnotes
{{custom_fn.content}}