Lossless Monitoring System for the Reliability Test to Electric Explosive Device

Qu Xiujie;Wang Wujun;Chu Enyi;Xie Gaodi

Acta Armamentarii ›› 2003, Vol. 24 ›› Issue (4) : 565-568. DOI: 10.3969/j.issn.1000-1093.2003.04.033
Research Notes

Lossless Monitoring System for the Reliability Test to Electric Explosive Device

  • Qu Xiujie, Wang Wujun, Chu Enyi, Xie Gaodi
Author information +
History +

Abstract

A monitoring system scheme for non-contact, lossless renaoility test of electric explosive ae- vice (LED) was proposed based on an analysis of all kinds of factors affecting EED reliability test especially the artificial and environmental factors. The scheme is based on the Hall effect principle of electromagnet?ics, using magnet-balanced current sensor as an electronic signal sensor, applying high spped A/D converter or converting board to transform the acquired signal into digital signals stored in random access memory for later processing. Development of the monitoring instrument can reduce human errors, increase ratios in test success, and improve tests on EED firing reliability.

Key words

electronic technique / electric explosive device / firing reliability test / Hall effect / microcon?troller

Cite this article

Download Citations
Qu Xiujie, Wang Wujun, Chu Enyi, Xie Gaodi. Lossless Monitoring System for the Reliability Test to Electric Explosive Device. Acta Armamentarii. 2003, 24(4): 565-568 https://doi.org/10.3969/j.issn.1000-1093.2003.04.033

References

[1] GJB376-87.火エ品可靠性评估方法.北京:国防科エ委军标出 版发行部,1988. 5,1?5
[2] 韩文.强电流脉冲放电技术.北京:淸华大学出版社,1989.154 ?161
[3] 胡汉才.单片机原理及其接ロ技术.北京:清华大学出版社, 1998.298?306